| Model | Combination | Dimension Range | Category |
| A60-01 | 19+20+6 | 2400*3600 | Wet |
| A60-02 | 15+9A+5+22+5 | 2400*3600 | Wet |
| A60-03 | 8+15A+27(5+6+5+6+5) | 2400*3600 | Dry |
| A60-04 | 12+1.52+6+15A+27(5+6+5+6+5) | 2400*3600 | Dry |
| Remarks: 1.The thickness of tempered glass: 5-22mm, the fire protection layer: 5-30mm, hollow layer: 6-24mm, which can be customized according to customers requirements. 2. It can be combined with Low-E glass to form energy-saving fireproof glass with U value of 1.0-1.6 and g value of 0.28-038. 3. It can be combined with electrically heated glass and bullet-proof glass to form electrically heated fireproof glass or bulet-proof fireproof glass. |
|||
| Wet A60 fireproof glass | Nano silicon (dry) A60 fireproof glass | |
| Main raw material | Acrylamide | Silicon dioxide |
| Spacing strip | Glass strip | Fireproof butyl rubber strip |
| Chemical properties of protective layer | Organic compound (gel-like) | Inorganic compound (solid state) |
| Weather resistance | - 40℃ - 45℃ | - 20℃ - 45℃ |
| Resistance to ultraviolet radiation | 400 hours | 2000 hours |
| Quality stability | 3-5 years | 10-25 years |
| Model | Combination & Thickness | Function | Range |
| JC-01 | 19+6 | Anti-smash and explosion-proof | 2000*3600 |
| JC-02 | 12+6+6 | Bulletproof (Type 79 Submachine Gun) | 2000*3600 |
| JC-03 | 36mm | Bulletproof (AK 47, Type 56) | 2000*3600 |
| JC-04 | 48mm | Bulletproof (79 sniper rifle, 85 sniper rifle) | 2000*3600 |
| Heating power (W/d㎡) | Outdoor minimum temperature | |
| Min | Max | |
| 7 | 9 | -12℃ |
| 12 | 15 | -28℃ |
| 17 | 21 | -40℃ |